Stripper column reboiler, Delta T
I am having troubles retaining upper and lower temperatures in my
stripper column. I have tried changing fluid levels, increasing steam,
and having very little success at raising my temperatures.
The
reboiler has been hydroblasted less than a 6 months ago. Any helpful
hints or things I can try to get this operating coorectly at the
temperatures I need to properly strip the water from the product?
If you have water in your stripped product(globle valve), you can look at the following:
- Reboiler duty. Calc it from steam or condensate flow rate.
- Low top temp. Calc the water dew point overhead to make sure water can leave overhead.
-
Vapour to liquid rate at bottom tray. You need a V/L mole ratio of at
least 0.3-0.5 to properly strip water or H2S. This becomes a problem
when you increase feed preheat too much.
- Lastly, if you control the
reboiler duty on outlet temperture, make sure the temperature have a
significant change for change in vaporization.