Covering of thermodynamic steam trap when it rains
Recently, our refinery have experienced higher steam consuming when it
rains and ,we think, one possible reason will be performance loss of
steam trap by higher heat loss on the surface(most of our traps are
thermodynamic type). In other words, vapor pressure on top of the trap
disk will be condensed by cold rain and it will not trap condensate
properly. Finally steam loss. Above is the logic we thought, so now we
are considering covering of steam trap. Re this matter please comment on
following question if you have good explanation.
a) Does the covering of steam trap(esp. thermodynamic
type) is common practice ?
b) If it is common pactice, how do you usually covering
steam trap ?
c) If you cover steam trap, how do you usually evaluate
the performance of steam trap cover ?
d) Any other method, improve steam trap performance loss
when it rain ?
Spirax has insulated TD traps, i.e the disc cover is insulated. I once
used these kind of traps for open area condensate lines. The rough
method is to collect condensate and check the performance before and
after insulation.
Also check for correct insulation thickness of
steam piping. There may be more condensate formation. Also check the
possibility of gaps between two insulation lengths(filter).
On the other hand if the non-insulated traps are then thermally
insulated, it may result in a situation, especially in summertime, of
not allowing the flash steam to condense more readily, holding down the
disc, not allowing sufficient condensate to pass.
Provided the
heat transfer is caused by ambient temperatures, such as at night, or in
winter, the cycles may become more frequent owing to the additional
heat loss. However, this may actually compensate for the added heat load
that the trapped unit would realize.
I fully adhere to quark's recommendations on measuring the amount of condensate before and after insulation.
The TD trap has a vapor pressure on top of the disc that keeps it in the
closed position. When this vapor condenses or leaks under the seat the
pressure drops and the trap opens. The trap will remain open untill
all of the condensate drains, more vapor will delvelop on top of the
disc, and the trap will close again.
When it rains, sure enought,
the trap cycles much quicker because the rain is condensing the vapor
on top of the disc. This will not only use a bit of steam but also
shorten the life of the TD trap.
Most manufacturers of TD's know
this. They make newer pre-insulated caps on the TD's, and they control
the cyclcing not by a loss of heat from the top but rather the finish on
the disc itself to allow a small leakage and the trap will cycle.
For
older traps, they make these little metal covers - a 'rain hat' that
will prevent this short cycling. In my experience, these do work,
however they do NOT last long - either getting blown away or not
replaced during a repair or trap checking cycle.
As for the trap
operation, they will make the trap cycle less frequently, but once the
trap does cycle open, it will drain all the condensate present. TD
traps are always beholden to this on/off cycle, in which the opening of
the trap is not tied to the amount of condensate that may be present.
For this reason, I have always preferred thermostatic traps on drip and tracer lines installed outside....